12.3 - Abutment Type A3 (insert sheets - none)

  • Plan View - Add to A3 notes to clarify which is for wing with pile and which is for wing without pile.

12.7 - Details For Wings Parallel to A1 Abutment Centerline (insert sheet - none) 

  • Wing Elevation - Remove reference to Bench Mark Cap.  WisDOT has discontinued the statewide practice of furnishing a survey disk to the contractor and requiring it to be placed in the parapet or the wing.

13.5 - Hammerhead Pier - Type 2 (insert sheets - none) 

  • Elevation View - Extend vertical bars in column to match the other vertical bars in the column.  Add footing dowels to ends of column.
  • Detail A - Add new detail to better show bar steel  in cap.

24.2 - Plate Girder Details (insert sheets - none) 

  • Stiff. & Conn. Stiff. To Web/Flange Conn. Welds Detail - Change all dimensions from edge of stiffener to weld to ¼ " min., ½ " max.  Change clip corner to 1" radius.

30.10 - Parapet Footing (insert sheets - footing.dgn, lfdec.dgn) 

  • Section Thru Parapet on Bridge - Remove note referencing chain link fence.  Change note referring to standard 30.11 to read "See std. 30.11 for additional post attachment & fence fabric details."

30.11 - Chain Link Fence Details (insert sheets - railchan.dgn)

  • Fence Part Elevation - Change all references to "stretcher bar" to "tension bar".  Show detail of top and bottom of fence to be knuckled.  Change note referring to chain link fabric to more closely match specification.


30.12 - Sloped Face Parapet 'LF' (insert sheets - lfdec.dgn, lfwin.dgn) 

  • Inside Elevation - Remove reference to Bench Mark Cap.  WisDOT has discontinued the statewide practice of furnishing a survey disk to the contractor and requiring it to be placed in the parapet or the wing.

30.13 - Sloped Face Parapet 'HF' (insert sheets - hfdec.dgn, hfwin.dgn) 

  • Inside Elevation - Remove reference to Bench Mark Cap.  WisDOT has discontinued the statewide practice of furnishing a survey disk to the contractor and requiring it to be placed in the parapet or the wing.

30.14 - Lighting Detail (insert sheets - lightdet.dgn) 

  • Anchorage Detail chart - Change dimension "E" to 2 11/16".  (Dimension on insert sheet is shown correctly.)

30.15 - Ornamental Protective Screening (insert sheets - screening.dgn) 

  • Inside Elevation of Railing - Change fence note to more closely match specification.  Show detail of top and bottom of fence to be knuckled.
  • Notes - Remove note beginning with "The end of the fabric shall be attached ....".

30.19 - Vertical Face Parapet 'TX' (insert sheets - railtex.dgn) 

  • Dimension Corrections.

30.20 - Sloped Face Parapet '51F' (insert sheets - 51f.dgn) 

  • Inside Elevation - Remove reference to Bench Mark Cap.  WisDOT has discontinued the statewide practice of furnishing a survey disk to the contractor and requiring it to be placed in the parapet or the wing.

37.1 - Pedestrian Overpass (insert sheets - none) 

  • Detail 'A' - Add "and fence fabric" to note
  • Notes - Remove note "Knuckle top and bottom .....")

37.2 - Pedestrian Overpass Details (insert sheets - none) 

  • Elevation of Fence - Show top and bottom of fence as knuckled.   Change "strecher bar" to "tension bar".

40.1 - Concrete Overlay (insert sheets - none) 

  • General Notes - bid item name correction.

40.2 - Asphaltic Overlay (insert sheets - none) 

  • General Notes - bid item name correction.